- How high must a guard be on a deck in Ontario?A guard must be at least 1 070 mm high, dropping to 900 mm where the walking surface it serves is not more than 1 800 mm above the finished ground.
- What is the minimum ceiling height for a bedroom in Ontario?Ontario requires 2 300 mm of clear height over at least 50% of the required floor area, or 2 100 mm over the whole required area.
- What ceiling height is required in a basement in Ontario?Ontario requires 2 100 mm of clear height over at least 75% of the basement floor area, with 1 950 mm permitted under beams and ducts.
- What ceiling height do I need for a basement apartment in Ontario?A secondary suite requires 1.95 m of clear height over the required floor area, reducing to 1.85 m under beams and ducts.
Why these requirements are written the way they are
Field Notes
Guards on Balconies and High Drops
Field NotesWhy Stair Guards Fail When Deck Guards Pass
Field NotesWhat a Basement Suite Has to Have
Code WatchRadon Rough-Ins: Cheap Now, Expensive Later
Ask about Ontario
Canadian Codes scopes every answer to a jurisdiction and cites the document, section, and page so you can check it yourself.