How high must a guard be on a deck in Ontario?

A guard must be at least 1 070 mm high, dropping to 900 mm where the walking surface it serves is not more than 1 800 mm above the finished ground.

Conditions and exceptions

  • A guard is required where the walking surface is more than 600 mm above the adjacent level.
  • The 900 mm allowance is for exterior guards serving a single dwelling unit.
  • Openings must not permit a 100 mm sphere to pass through.
  • Toronto and other municipalities administer the Ontario Building Code but may add permit conditions.

Where this comes from

Governing document

Ontario Building Code

This page states the requirement and points you to the publisher. It does not reproduce the code text — read the provision itself at the official source below.

Read the official text at Ontario — King's Printer →

Verify this against the code edition actually adopted where you are building. Provinces, territories, and municipalities amend on their own schedules, and where the governing document and this page disagree, the governing document controls. This is not legal, engineering, or permitting advice. Last reviewed 2026-08-12.