Manitoba
Manitoba code requirements
Each page states the requirement, the conditions that come with it, and the document it comes from. Verify against the edition actually adopted where you are building — these pages point you to the publisher rather than reproducing the code text.
- Does the Manitoba Building Code apply to a shed under 10 m²?A building not greater than 10 m² in building area is excluded, provided the authority having jurisdiction is satisfied it does not create a hazard.
- Where are carbon monoxide alarms required in Manitoba?A CO alarm is required in the same room as a permanently installed fuel-burning appliance, in a room adjacent to and within 5 m of one, and centrally located on every storey adjacent to a storage garage.
- What size egress window does a Manitoba basement need?The window needs an unobstructed opening of at least 0.385 m² with no dimension less than 500 mm, a sill not more than 150 mm above the floor, and any window well giving at least 550 mm of clearance.
- What fire separation is required between an attached garage and a Manitoba dwelling?A storage garage must be separated from other occupancies by a vertical assembly with a fire-resistance rating of not less than 45 min, rising to not less than 1 h where an occupancy is above the garage.
Why these requirements are written the way they are
Field Notes
Site Servicing Runs Ahead of the Building Permit
Field NotesWhat Counts as a Structural Change
Field NotesWhere Carbon Monoxide Alarms Go
Field NotesWhat a Basement Suite Has to Have
Field NotesBuilding for Wildfire: Embers First
Ask about Manitoba
Canadian Codes scopes every answer to a jurisdiction and cites the document, section, and page so you can check it yourself.
Try it free →